3.2.4.2. ÈçºÎʹÓÃFTPÔÚPCºÍAS/400Ö®¼ä´«Êä°üº¬ÖÐÎĵÄÎļþ
A. Ãæ°åµ÷³É 01 D M
V=F Æô¶¯ , ·ÅÈëI_BASE_01¹âÅÌ , ÓÃCLIENT
ACCESSÁ¬½ÓAS400 (³õʼDSTÓû§¼°¿ÚÁî¾ùΪQSECOFR), Ñ¡ÔñÓïÑÔ, NEXT , ³öÏÖÏÂÃæµÄ½çÃæ , Ñ¡Ôñ2 , NEXT
Install Licensed Internal Code
System: 12345678
Select one of the following:
1. Install
Licensed Internal Code
2. Work with Dedicated Service Tools (DST)
3. Define
alternate installation device
Selection
2
Licensed Internal Code - Property of IBM
5722-999 Licensed
Internal Code (c)
Copyright IBM Corp. 1980, 2001.
All
rights reserved.
US Government Users Restricted
Rights -
Use duplication or disclosure restricted
by GSA ADP schedule
Contract with IBM Corp.
B.
ÊäÈëQSECOFRÓû§¼°ÆäÃÜÂë , NEXT
Dedicated Service Tools (DST) Sign On
System: 12345678
Type choices, press Enter.
Service tools user . . . . . . . .
. . . QSECOFR
Service tools password . . . . . .
. £ª£ª£ª£ª£ª£ª
F3=Exit F5=Change password F12=Cancel
C.
Ñ¡Ôñ3 , NEXT
Use Dedicated Service Tools (DST)
System: 12345678
Select one of the following:
1. Install
Licensed Internal Code
2. Work with
disk units
3. Work with DST environment
4. Start a
service tool
5. Work with
remote service support
Selection
3
F3=Exit F12=Cancel
D.
Ñ¡Ôñ3 , NEXT
Work with DST Environment
System: 12345678
Select one of the following:
1. Active
service tools
2. System
devices
3. Service tools user profile
Selection
3
F3=Exit F12=Cancel
E.
Ñ¡Ôñ2 , NEXT
Work with Service Tools User Profile
System: 12345678
Type option, press Enter.
2=Change password 4=Display 8=Change
description
User
Opt
Profile Description
Status
2 QSECOFR QSECOFR
Enabled
F3=Exit F5=Refresh F12=Cancel
F.
ÊäÈëÐÂÃÜÂë , NEXT
Change Service Tools User Password
System: 12345678
Service tools user profile name . . . . .
: QSECOFR
Password last changed . . . . . . . . . .
:
Type choices, press Enter.
Current password . . . . . . . . . . . . £ª£ª£ª£ª£ª£ª£ª
New password . . . . . . . . . . . . . . £ª£ª£ª£ª£ª£ª£ª
New password (to
verify) . . . . . . . £ª£ª£ª£ª£ª£ª£ª
F3=Exit F12=Cancel
×¢Òâ: ÐÂÃÜÂë²»ÄÜÓë¾ÉÃÜÂëÏàͬ
A.
Ãæ°åµ÷³É 01 B M V=F Æô¶¯ , ÓÃCLIENT ACCESSÁ¬½ÓAS400, ³öÏÖÏÂÃæµÄ½çÃæ , Ñ¡Ôñ3
, NEXT
IPL
or Install the System
System: 12345678
Select one of the following:
1. Perform an
IPL
2. Install the
operating system
3. Use Dedicated Service Tools (DST)
4. Perform
automatic installation of the operating system
5. Save Licensed
Internal Code
Selection
3
Licensed Internal Code - Property of IBM
5722-999 Licensed
Internal Code (c)
Copyright IBM Corp. 1980, 2001.
All
rights
reserved. US Government Users
Restricted Rights -
Use duplication or disclosure restricted
by GSA ADP schedule
Contract with IBM Corp.
B.
³öÏÖÒÔϽçÃæ , ÊäÈëQSECOFRÓû§¼°ÆäÃÜÂë , NEXT
Dedicated Service Tools (DST) Sign On
System: 12345678
Type choices, press Enter.
Service tools user . . . . . . . .
. . . ¡¡QSECOFR
Service tools password . . . . . .
. . . £ª£ª£ª£ª£ª£ª£ª
F3=Exit F5=Change password F12=Cancel
C.
Ñ¡Ôñ5 , NEXT
Use Dedicated Service Tools (DST)
System: 12345678
Select one of the following:
1. Perform an
IPL
2. Install the operating
system
3. Work with
Licensed Internal Code
4. Work with
disk units
5. Work with DST environment
6. Select DST
console mode
7. Start a
service tool
8. Perform
automatic installation of the operating system
9. Work with
save storage and restore storage
10. Work with remote
service support
Selection
5
F3=Exit F12=Cancel
D.
Ñ¡Ôñ6 , NEXT
Work with DST Environment
System: 12345678
Select one of the following:
1. Active
service tools
2. System
devices
3. Service tools
user profiles
4. System
values
5. Service tools
device profiles
6. Service tools security data
Selection
6
F3=Exit F12=Cancel
E.
Ñ¡Ôñ1 , NEXT
Work with Service Tools Security Data
System: 12345678
Select one of the following:
1. Reset operating system default password
2. Change
operating system install security
3. Work with
service tools security log
4. Restore
service tools security data
5. Save service
tools security data
6. Password
level
Selection
1
F3=Exit F12=Cancel
F.
NEXT
Confirm Reset of System Default Password
System: 12345678
Press Enter to confirm your choice to
reset the operating
system
security officer sign-on password.
The password will
be reset
to the default assigned when the system was shipped.
Press F12 to return to change your
choice.
F12=Cancel
Operating system password override not in
effect
G.
IPL
ϵͳ°²È«ÐÔÊÇÓɲÙ×÷ϵͳÌṩµÄһϵÁб£»¤´ëÊ©¡£Ê¹ÏµÍ³¹ÜÀíÔ±Äܹ»±£»¤ºÍ¿ØÖÆϵͳÉ豸¡¢Êý¾Ý¡¢³ÌÐòµÈ×ÊÔ´µÄʹÓ㬲¢ÇÒÄܹ»·ÀֹżȻʹʻòÕßÐîÒâÆÆ»µµÄ·¢Éú¡£ÏµÍ³°²È«ÐԵĻù±¾ÄÚÈÝ°üÀ¨£º
¡¤
ÎïÀí°²È«ÐÔ
¡¤
°²È«¼¶±ð
¡¤
Óû§ÌØÕ÷Îļþ£¨User Profile£©
¡¤
Óû§¼¶±ð
¡¤
Áª»ú°²È«£¨Sign On£©
¡¤
×ÊÔ´°²È«
ÎïÀí°²È«ÐÔÖ÷Òª±£»¤É豸¼°½éÖʲ»ÊÜËðÉ˺ÍÆÆ»µ¡£²ÉÈ¡µÄ´ëÊ©Ö®Ò»ÊÇ£¬ÔÚϵͳ¿ØÖÆ°åÉÏ£¬Ê¹ÓÃËø¿ª¹Ø¿ÉÒÔÏÞÖÆϵͳµÄʹÓá£Ëø¿ª¹Ø¹²ÓÐËĸöλÖãºÊÖ¶¯£¨Manual£©¡¢³£¹æ£¨Normal£©¡¢×Ô¶¯£¨Auto£©¼°°²È«£¨Secure£©¡£(¶ÔÓÚһЩÀϵĻúÐÍ»òÕßС»úÆ÷£¬ÓеÄûÓÐsecureÑ¡Ïî)
ϱíÏÔʾÿ¸öËøÁªÎ»ÖÿÉÒÔ×öÄÄЩ²Ù×÷:
²Ù ×÷ |
ÊÖ ¶¯ |
³£ ¹æ |
×Ô ¶¯ |
°²È« |
ÊÖ¶¯×°Èëϵͳ |
¿É |
·ñ |
·ñ |
·ñ |
×Ô¶¯×°Èëϵͳ |
¿É |
¿É |
·ñ |
·ñ |
ÊÖ¶¯¿ØÖƹ¦ÄÜ |
¿É |
·ñ |
·ñ |
·ñ |
×Ô¶¯²Ù×÷ÈçÔËÐÐ IPL |
·ñ |
¿É |
¿É |
·ñ |
ÖÕ¶ËÉÏÓùرÕϵͳÃüÁî (PWRDWNSYS) ¹Ø±Õϵͳ |
¿É |
¿É |
¿É |
¿É |
ÓõçÔ´¿ª¹Ø¸øϵͳϵç |
¿É |
·ñ |
·ñ |
·ñ |
ÓõçÔ´¿ª¹Ø¸øϵͳÉϵç |
¿É |
¿É |
·ñ |
·ñ |
ϵͳ³õʼ³ÌÐò×°Èë |
¿É |
·ñ |
·ñ |
·ñ |
Ñ¡Ôñ×°È벻ͬµÄϵͳ |
¿É |
·ñ |
·ñ |
·ñ |
Ö´ÐÐרÓ÷þÎñ¹¤¾ß¹¦ÄÜ |
¿É |
·ñ |
·ñ |
·ñ |
×¢Ò⣺
½öÔÚ×°Èëϵͳʱ£¬Ñ¡Ôñ²»Í¬³õʼ³ÌÐò×°È뷽ʽ£¬»òÕßʹÓÃרÓù¤¾ßʱʹÓÃËøµÄÊÖ¹¤Î»Öá£ÉÏÊöËĸöλÖã¬Ô¿³×¿É´ÓËø¿×ÖÐÄóöÀ´£¬²¢ÇÒ±£³ÖËøµÄÔλ¡£Ñ¡ÔñÄãËùÒªÇóµÄλÖò¢ÇÒÄÃ×ßÔ¿³×¡£Îª·ÀÖ¹Óû§ÊÖ¶¯¸øϵͳϵ磬½¨Á¢½«ÐÎ×´¶¨ÔÚ¡°³£¹æ¡±Î»¡£
ÐÂ×° OS/400 ÊÇûÓпÚÁîºÍ×ÊÔ´°²È«µÄ¹ÜÀí¡£ÕâÒâζ×ÅÈκÎÓû§¿ÉÒÔʹÓÃÈκÎ×ÊÔ´¡£Òò´Ë£¬Óû§Ó¦¸ÃÊ×ÏÈͨ¹ýÃüÁî
CHGSYSVAL »ò WRKSYSVAL ÐÞ¸Äϵͳֵ QSECURITY£¬ È»ºó×öÒ»´Îϵͳ³õʼ³ÌÐò×°È루IPL£©¡£
ϱí±È½ÏÁËϵͳµÄ²»Í¬°²È«¼¶±ð:
¹¦ ÄÜ |
¼¶ ±ð 10 |
¼¶±ð 20 |
¼¶ ±ð 30 |
¼¶ ±ð 40 |
½øÈëϵͳÐèÒªÓû§Ãû |
ÊÇ |
ÊÇ |
ÊÇ |
ÊÇ |
½øÈëϵͳÐèÒª¿ÚÁî |
·ñ |
ÊÇ |
ÊÇ |
ÊÇ |
¼¤»î¿ÚÁȫ¹ÜÀí |
·ñ |
ÊÇ |
ÊÇ |
ÊÇ |
¼¤»î×ÊÔ´°²È«¹ÜÀí |
·ñ |
·ñ |
ÊÇ |
ÊÇ |
¼¤»î²Ëµ¥¼°³õʼ³ÌÐò°²È«¹ÜÀí |
·ñ |
ÊÇ |
ÊÇ |
ÊÇ |
¿É´æÈ¡ÈκÎÄ¿±ê |
ÊÇ |
ÊÇ |
·ñ |
·ñ |
Óû§ÌØÐÔÎļþ×Ô¶¯Éú³É |
ÊÇ |
·ñ |
·ñ |
·ñ |
ÔÚϵͳ¼à²âÈÕÖ¾ÖмǼÄÇЩʹÓò»Ö§³ÖµÄ½çÃæÀ´´æÈ¡Ä¿±êµÄËùÓгÌÐò |
ÊÇ |
ÊÇ |
ÊÇ |
ÊÇ |
ÔÚϵͳ¼à²âÈÕÖ¾ÖмǼÄÇЩ±»ÏÞÖƱàÒëµÄ³ÌÐòÖ¸Áî |
ÊÇ |
ÊÇ |
ÊÇ |
ÊÇ |
ʹÓÃδ֧³ÖµÄ½çÃæÀ´´æÈ¡Ä¿±êµÄ³ÌÐòÔÚÔËÐÐʱʧ°Ü |
·ñ |
·ñ |
·ñ |
ÊÇ |
×¢£ºV5R1ÒԺ󣬰²È«¼¶±ð10²»ÔÙÌṩ¡£¶ÔÓÚÓɵͰ汾Éý¼¶ÎªV5R1Ò»Ñù°æ±¾µÄϵͳ£¬½«±£ÁôÒÔÇ°µÄ°²È«¼¶±ð¡£
Óû§ÌØÕ÷Îļþ£¨*USRPRF£©ÊÇ°²È«¹ÜÀíµÄÒ»¸öÖØÒª²¿·Ö£¬ËüÊÇÓÃÀ´ÑéÃ÷Óû§ÊÇ·ñÄܽøÈëϵͳ£¬ÒÔ¼°½øÈëϵͳºó¿ÉÒÔʹÓÃÄÄЩϵͳ×ÊÔ´¡£Óû§ÌØÕ÷ÎļþÖ»ÄÜÓÉÓû§¼¶±ðΪ°²È«¹ÜÀí¹ÙÔ±£¨*
SECOFR£©»ò°²È«¹ÜÀíÔ±£¨* SECADM£©µÄÓû§½¨Á¢»òÐ޸ģ¬Ê¹ÓÃÃüÁî CRTUSRPRF »ò CHGUSRPRF¡£Óû§ÌØÕ÷ÎļþÖаüº¬ÁËÓйØÓû§µÄËùÓвÙ×÷ÐÅÏ¢£¬Ö÷Òª¼¸ÏîÐÅÏ¢°üÀ¨£º
¡¤
USRPRF ÌØÕ÷ÎļþÃû¼´Óû§±êʶ£¨USERID£©£¬³¤¶ÈΪ 10 ¸ö×Ö·û¡£
¡¤
PASSWORD ¿ÚÁһ°ãÉèÖÃÓë * USRPRF Ò»Ñù£¬ÔÙÓÉÓû§×ÔÐÐÐ޸ģ¬³¤¶ÈΪ
10 ×Ö·û¡£
¡¤
STATUS ״̬£¬Ö»ÓÐÔÚ * ENABLED ״̬Ï£¬ÌØÕ÷Îļþ²ÅÉúЧ¡£
¡¤
USRCLS 5¸öµÈ¼¶:Óû§,ϵͳ²Ù×÷Ô±,³ÌÐòÔ±,°²È«¹ÜÀíÔ±ºÍ°²È«¹ÜÀí¹ÙÔ±
¡¤
CURLIB µ±Ç°¿â£¬Ö¸¶¨ÏµÍ³ËÑË÷Ä¿±êµÄµÚÒ»¸ö¿â¡£
¡¤
INLPGM ³õʼ³ÌÐò£¬µ±½øÈëϵͳʱ£¬¿ÉÒÔÖ¸¶¨Ò»¸öÒªµ÷ÓõijÌÐòÃû¡£
¡¤
LMTCPB ÏÞ¶¨ÄÜÁ¦£¬*YES Ñ¡Ôñ¿ÉÒÔÏÞÖÆÓû§Ê¹Óò˵¥ºÍÃüÁîÐеÄÄÜÁ¦¡£
¡¤
MSGQ ÐÅÏ¢¶ÓÁУ¬È±Ê¡Öµ *USRPRF£¬Èç¹ûʹÓñðµÄÐÅÏ¢¶ÓÁУ¬ÔòÊÂÏÈÒª½¨Á¢¡£
¡¤
DLVRY ÐÅÏ¢´«µÝ·½Ê½£¬¹²ÓÐËÄÖÖ£ºµ±ÐÅÏ¢¶ÓÁÐÊÕµ½ÐÅϢʱ£¬*NOTIFY ×÷Òµ±»Ìáʾ;
*BREAK
×÷Òµ±»ÖжÏ; *HOLD
ÐÅÏ¢±»¹ÒÆð; *DFT »Ø´ðÐÅϢʹÓÃȱʡֵ¡£
¡¤
OUTQ Êä³ö¶ÓÁУ¬×îºÃÿ¸öÓû§Ö¸¶¨Ò»Êä³ö¶ÓÁÐ,ÐèÒªÊÂÏȽ¨Á¢¡£
Óû§¼¶±ð¾ö¶¨Óû§ÄÜʹÓÃÄÄЩ¿ØÖƹ¦ÄܺͲ˵¥Ñ¡Ôñ¡£
ϱíÏÔʾϵͳȱʡÌØÊâȨÏÞ¡£
Special
Authority for Level 30 or above |
||||||
User
Class ALLOBJ SECADM SAVSYS JOBCTL SERVICE SPLCTL |
||||||
SECOFR |
5 |
5
|
5
|
5 |
5
|
5 |
SECADM |
|
5 |
5
|
5 |
|
|
PGMR |
|
|
5 |
5 |
|
|
SYSOPR |
|
|
5 |
5 |
|
|
USER |
NO
|
special |
authority |
|
|
|
ÆäÖУº
* ALLOBJ ÓÐȨʹÓÃËùÓеÄϵͳĿ±ê¡£
* SECADM ÓÐȨʹÓð²È«¹ÜÀí¹¦ÄÜ£¬½¨Á¢ºÍÐÞ¸ÄÓû§
ÌØÕ÷Îļþ¡£
* SAVSYS ÓÐȨʹÓñ¸·ÝºÍ»Ö¸´¹¦ÄÜ¡£
* JOBCTL ÓÐȨʹÓÃ×÷Òµ¿ØÖƹ¦ÄÜ£¬°üÀ¨Êä³ö¶ÓÁС¢
´òÓ¡ºÍ×Óϵͳ¡£
* SERVICE ÓÐȨʹÓ÷þÎñ¹¦ÄÜ¡£
*
SPLCTL ÓÐȨʹÓüÙÍÑ»ú¿ØÖÆ¡£
Óû§µÇ¼ϵͳ£¬±ØÐëÔÚÁª»ú£¨Sign On£©»ÃæÉÏ£¬ÊäÈëÕýÈ·µÄÓû§±êʶºÍ¿ÚÁî¡£Áª»ú»ÃæÉÏ»¹¿ÉÒÔÖ¸¶¨µ÷ÓõijÌÐòÃû¡¢²Ëµ¥ÃûºÍµ±Ç°¿âÃû¡£Ð޸ĿÚÁîʹÓÃÃüÁî
CHGPWD¡£
×¢²áϵͳʱ£¬ÓйؿÚÁîµÄÏÞÖÆ£¬ÔÚϵͳÖоßÓжàÏî˵Ã÷£¨È«²¿¾ßÓÐ SEC ÀàÐÍ£©£º
¡¤
QLMTDEVSSN£º ¾ö¶¨Óû§ÊÇ·ñ¿ÉÒÔÔÚ¶à¸öÖÕ¶ËÉϵǼ¡£
¡¤
QMAXSIGN£º ¾ö¶¨Óû§ÎÞЧµÇ¼µÄ×î´ó´ÎÊý£¬×î´óΪ
*NOMAX¡£
¡¤
QMAXSGNACN£º µ±ÎÞЧµÇ¼´ïµ½×î´ó´ÎÊýʱ£¬ÏµÍ³Ó¦²ÉÈ¡µÄ
Ðж¯£¬Ê¹É豸»òÓû§ÌØÕ÷Îļþ»òÁ½Õß±äΪÎÞ
Ч¡£
¡¤
QPWDEXPITV£º ¾ö¶¨¿ÚÁîÓÐЧµÄ×î´óÌìÊý£¬×î´óΪ
*NOMAX¡£
¡¤
QPWDMINLEN£º ¾ö¶¨¿ÚÁîÖÐ×Ö·ûµÄ×îС¸öÊý¡£
¡¤
QPWDMAXLEN£º ¾ö¶¨¿ÚÁîÖÐ×Ö·ûµÄ×î´ó¸öÊý¡£
¡¤
QPWDRQDDIF£º ¾ö¶¨Ð¿ÚÁîÊÇ·ñ²»Í¬ÓÚÇ°¼¸¸ö¿ÚÁî¡£
×ÊÔ´°²È«¹ÜÀíÖ÷ÒªÕë¶ÔϵͳĿ±ê¶øÑÔ£¬±£Ö¤Ö»ÓÐÊÚȨÓû§²Å¿ÉÒÔʹÓá£Èç¿â¡¢Îļþ¡¢³ÌÐò¡¢É豸µÈ¡£
ϵͳȨÏÞ·ÖΪÁ½¸öÖ÷ÒªÀàÐÍ£ºÌØÊâȨÏÞºÍÖ¸¶¨È¨ÏÞ¡£ÌØÊâȨÏÞÊÇÓÉÓû§ÌØÕ÷ÎļþÀ´¶¨ÒåµÄ£»Ö¸¶¨È¨ÏÞÔòÔÊÐíÓû§¶ÔϵͳĿ±êÖ¸¶¨²Ù×÷¡£Ö¸¶¨È¨ÏÞʹÓÃÃüÁ GRTOBJAUT À´ÊÚȨ£¬Ê¹Óà RVKOBJAUT À´ÊÕ»ØȨÏÞ£¬»òÕßʹÓÃÃüÁî EDTOBJAUT ±à¼È¨ÏÞ¡£
ÏÂͼ´óÖ±íʾϵͳÖÐȨÏÞµÄÀàÐÍ£º(ͼ»µÄ²»ºÃÇë¼ûÁÂ!:))
System
Authority
Special
Private
*EXCLUDE
*ALLOBJ
User-Defined
System
*SECADM
Defined
*all
*SAVSYS L
*JOBCTL Object Data
Authority
Authority
*CHANGE
*SERVICE
*USE
*SPLCTL
*OBJOPR
*READ
*OBJMGT
*ADD
*OBJEXIST
*UPD
*AUTLMGT
*DLT
Óû§¶¨ÒåµÄȨÏÞ¼¯°üÀ¨£º
l
Ä¿±êȨÏÞ
*
OBJOPR ²Ù×÷ȨÏÞ£¬ÔÊÐí²ì¿´Ä¿±êÃèÊö£»
*
OBJMGT ¹ÜÀíȨÏÞ£¬ÔÊÐí¶¨ÒåÄ¿±ê°²È«È¨ÏÞ£¬ÖØÃüÃûÄ¿
±ê£¬ÒÔ¼°Ôö¼ÓÊý¾Ý¿âÎļþ³ÉÔ±£»
*
OBJEXIST ´æÔÚȨÏÞ,ÔÊÐí¿ØÖÆÄ¿±ê´æÔÚ,ɾ³ýÄ¿±ê,ÊÍ·Å¿Õ¼ä,
±¸·Ý¼°»Ö¸´¡£
*
AUTLMGT ȨÏÞ±í¹ÜÀí¡£ÔÊÐíÔÚÒ»¸öȨÏÞ±íÉÏÔö¼ÓºÍɾ³ý
Óû§¼°ÆäȨÏÞ¡£
l
Êý¾ÝȨÏÞ
* READ ¶ÁȨÏÞ£¬ÔÊÐíÏÔʾĿ±êÄÚÈÝ»òÔËÐÐÒ»¸ö³ÌÐò£»
* ADD Ôö¼ÓȨÏÞ£¬ÔÊÐí¶ÔÄ¿±êÔö¼ÓÏîÄ¿;
* UPD ÐÞ¸ÄȨÏÞ£¬ÔÊÐíÐÞ¸ÄÄ¿±êÖеÄÏîÄ¿£»
* DLT ɾ³ýȨÏÞ£¬ÔÊÐí´ÓÄ¿±êÖÐɾ³ýÏîÄ¿¡£
ϵͳ¶¨ÒåµÄȨÏÞ¼¯°üÀ¨£º
* ALL Ìṩ¶ÔÄ¿±êµÄËùÓÐÄ¿±êȨÏÞºÍÊý¾ÝȨÏÞ£»
*
CHANGE Ìṩ¶ÔÄ¿±êµÄ²Ù×÷ȨÏÞºÍËùÓÐÊý¾ÝȨÏÞ£»
* USE Ìṩ¶ÔÄ¿±êµÄ²Ù×÷ȨÏÞºÍÊý¾Ý¶ÁȨÏÞ£»
*
EXCLUDE ¾Ü¾ø¶ÔÄ¿±êµÄÈκηÃÎʺͲÙ×÷¡£
ϱíÏÔʾϵͳ¶¨ÒåÓëÓû§¶¨ÒåÖ®¼äµÄ¹Øϵ¡£
System-Defined Authority |
|
|||||||
Authority |
Object OPR |
MGT |
EXIST |
Data READ |
ADD |
UPD |
DLT |
|
*ALL |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
|
*Change |
5 |
|
|
5 |
5 |
5 |
5 |
|
*Use |
5 |
|
|
5 |
|
|
|
|
*Exclude |
No |
authority |
|
|
|
|
|
|
AS400×Ô¶¯±¸·ÝÉèÖ÷½·¨
µÚÒ»²½£ºµÇ½AS/400Ö÷»ú
µÚ¶þ²½£º²é¿´±¸·Ý½á¹û£¨¸Ã²½·Ç³£ÖØÒª£¬ÓÃÓÚÈ·¶¨±¸·ÝÊÇ·ñ³É¹¦£©
ÔÚÃüÁîÐÐÊäÈëWRKSPLFÃüÁîºóµã»÷£¨ENTER»òCTRL£©£¬´ËÃüÁîÊDz鿴±¸·ÝÎļþµÄ´òÓ¡½á¹û¡££¨Ö»Óе±Ìá½»±¸·ÝÃüÁîʱ²ÎÊý
outputÑ¡Ôñ*printʱ£¬²Å»áÔÚSPLFÖвúÉú¸Ã½á¹û£©
µÚÈý²½£º²é¿´´òÓ¡ÄÚÈÝ£¬Èç¹ûÎļþÒ³ÊýºÜ¶à¿ÉÒÔÓÃPAGEUP¡¢PAGEDOWN½øÐзҳµÄ²Ù×÷£¬
ÔÚ×îÏÂÃæµÄÎļþÊÇ×îÐÂÉú³ÉµÄ£¬°´F11¿ÉÒÔ¿´±¸·Ýʱ¼ä£¬ÕÒµ½Ò»¸öÎļþÊÇ
QPSAVOBJ
ÓÃ5½øÈ¥²é¿´£¬ÔÚÎļþµÄÇ°ÃæÊäÈë5ºó°´£¨ENTER»òCTRL£©½øÈëÃ÷ϸÄÚÈÝ¡£
µÚËIJ½£ºÔÚ½øÈë´òÓ¡Îļþºó£¬×¢Òâ¿´Ò»ÏÂÈÕÆÚÊÇ·ñÊÇ×î½ü±£´æµÄ¼Ç¼£¬ÔÚÒ³ÃæÉÏ·½µÄCONTROLºóÃæµÄºáÏßÉÏÊäÈëB£¨B±íʾҪµ½ÎļþµÄ×îºó£»T±íʾҪµ½ÎļþµÄ¿ªÍ·£©¡£
×¢Ò⣺Ҫ¿´¿´NOT SAVEDµÄÎļþÊÇ·ñÊÇ0»òÕßÊÇ3£¬Èç¹ûÊǶþÕßÖ®Ò»¶¼ÊÇÕýÈ·µÄ£¨ÒòΪ±¸·Ý³ÌÐòÓÐ3¸ö´ò°üÎļþ£¬±£´æºÍ²»±£´æ¶¼ÊÇÕýÈ·µÄ£©Èç¹û´óÓÚ3¾ÍÊÇÓÐÎÊÌâ¡£
Library
------Objects------
File
File
Library Saved Saved Not saved Volume Label
Seque
ERP
YES 635 0 CASE4 ERP
* * * * * E N D O F L I S T I N G * * *
¿´ÍêÃ÷ϸÄÚÈݺó°´F3Ò»Ö±Í˵½Ö÷»Ãæ¡£
µÚÎå²½£º¼Æ»®Åú´¦ÀíÈÎÎñ
ÔÚÖ÷»ÃæµÄÃüÁîÐÐÉÏÊäÈëWRKJOBSCDEºó°´£¨ENTER»òCTRL£©
µÚÁù²½£º½øÈëʱ¼ä±íºóÔÚDAILYBAKÎļþµÄÇ°ÃæÊäÈë2×¼±¸½øÐÐÐ޸ģ¬»òÕß°´F6°´¼üÌí¼ÓÒ»¸öеÄ×÷Òµµ÷¶ÈÈÎÎñ¡££¨DAILYBAKΪ²âÊÔÓõĵ÷¶È×÷ÒµÃû£©
µÚÆß²½£ºÔڼƻ®Ê±¼äµÄºóÃæÐÞ¸Äʱ¼ä£¬¸Ä³ÉÒª±¸·ÝµÄÈÕÆÚºÍʱ¼ä¡£
Schedule date,
or . . . . . . . '
Schedule day . . . .
. . . . . . *NONE
+ for more values
Schedule time . . . . . . . . . '23:30:00'
¸ÄÍêºó°´£¨ENTER»òCTRL£©±£´æÍ˳ö¡£Í˳öºó¿´DAILYBAKÊÇ·ñ±£´æ³É¹¦£¬Èç¹ûSTATUSÊÇSCD£¬²¢ÇÒÈÕÆÚÊÇÐèÒª±¸·ÝµÄÈÕÆÚ¾ÍÊDZ£´æ³É¹¦ÁË¡£
-----Schedule------
Recovery
Submit
Opt Job
Status Date Time Frequency Action Date
DAILYBAK SCD
È·Èϱ¸·Ý×÷ÒµÊÇÕýÈ·µÄ²¢ÇÒÒѾ±£´æ³É¹¦ºóÔÙ°´F3Ö±µ½Í˵½Ö÷»Ãæ¡£
µÚ°Ë²½£º¶ÔÓÚеĴŴø£¬±¸·ÝÇ°ÐèÒª³õʼ»¯´Å´ø
ÃüÁ inztap
µÚ¾Å²½£ºÔÚ´ËÆÁÖеÄÐÅÏ¢±ØÐëÑϸñ°´ÒÔϵÄÄÚÈÝÌîд
Device . . . . . . . . .
. . . . tap01
Name
New volume
identifier . . . . . case5
Character value, *NONE...
New owner identifier . . .
. . . case5
Volume identifier . . . . . . . *MOUNTED Character value,
*MOUNTED
Check for active files .
. . . . *no
*YES, *NO, *FIRST
Tape density . . . . . .
. . . . *qic4gb *DEVTYPE,
*CTGTYPE, *QIC120..
Code . . . . . . . . . .
. . . . *EBCDIC *EBCDIC,
*ASCII
End of tape option . . .
. . . . *REWIND *REWIND,
*UNLOAD
Clear . . . . . . . . . . . . . *NO
*NO, *YES
ÒÔÉÏÔÚidentifierºóÌîдµÄCASE5ÖеÄ5´ú±íµÄÊÇÐÇÆÚÎåµÄ±¸·Ý´ø¡£
ÌîдÕýÈ·ºó°´£¨ENTER»òCTRL£©È·ÈÏ£¬ÐèÒªµÈÒ»»á£¨´óÔ¼3·ÖÖÓ£©ºó³öÏÖÒ»¸öÏûÏ¢£¬
Volume CASE5
prepared for operation with owner ID CASE5 ±íʾ´Å´øÒѾ¸ñʽ»¯Íê³É¡£
µÚÊ®²½£ºÔÚÖ÷»ÃæÔÚµÄÃüÁîÐÐÉÏÊäÈë90£¨±íʾÍ˳ö£©°´£¨ENTER»òCTRL£©ºóÍ˳öAS400¡£
µÚʮһ²½£ºÈç¹ûÔÚÆÁÄ»²Ù×÷Öйâ±êûÓÐÔÚOPTµÄλÖÃÉϾͰ´ÁË5£¨DISPLAY£©
»òÕß2£¨CHANGE£©£¬ÆÁÄ»Õâʱ»á±»ËøËÀ£¬ÆÁÄ»µÄ×óϽǻá³öÏÖºìÉ«µÄ0005·ûºÅ£¨ÔÚÆäËûµÄ´íÎó²Ù×÷ʱҲ»á³öÏÖºìÉ«µÄ0005·ûºÅ£©£¬Õâʱ±ØÐë°´¿ØÖÆ̨¼üÅÌ×óÏÂ
½ÇµÄRESET£¨QUIT£©¼ü²Å¿ÉÒÔ»Ö¸´²Ù×÷¡£
FTPÊÇÈçºÎ¹¤×÷µÄ
FTPÊÇ»ùÓÚ¿Í»§£·þÎñÆ÷Ä£ÐͶøÉè¼ÆµÄ¡£¿Í»§ºÍ·þÎñÆ÷Ö®¼äÀûÓÃTCPÖ±½ÓÁ¬½Ó¡£ÓëÆäËü¿Í»§£·þÎñÆ÷Ä£ÐͲ»Í¬µÄÊÇ£ºFTP¿Í»§Óë·þÎñÆ÷Ö®¼äÊÇÒª½¨Á¢Ë«ÖØÁ¬½Ó£ºÒ»¸öÊÇ¿ØÖÆÁ¬½Ó£¬Ò»¸öÊÇÊý¾ÝÁ¬½Ó¡£½¨Á¢Ë«ÖØÁ¬½ÓµÄÔÒòÔÚÓÚFTPÊÇÒ»¸ö½»»¥»á»°ÏµÍ³£¬Ä³¿Í»§Ã¿´Îµ÷ÓÃFTP£¬±ãÓë·þÎñÆ÷½¨Á¢Ò»¸ö»á»°£¬»á»°ÒÔ¿ØÖÆÁ¬½ÓÀ´Î¬³Ö£¬Ö±µ½Í˳öFTP¡£¿ØÖÆÁ¬½Ó¸ºÔð´«Êä¿ØÖÆÐÅÏ¢£¬ÓÈÆäÊÇ¿Í»§¿Í»§ÃüÁ±ÈÈçÎļþ´«ÊäÃüÁîµÈµÈ£©¡£ÀûÓÿØÖÆÃüÁ¿Í»§¿ÉÒÔÏò·þÎñÆ÷Ìá³öÎÞÊý´ÎµÄÇëÇó£¨Ò»¸ö¿Í»§ÃüÁî¾ÍÊÇÒ»¸öÇëÇ󣩡£¿Í»§Ã¿Ìá³öÒ»¸öÇëÇ󣬷þÎñÆ÷ÔÙÓë¿Í»§½¨Á¢Ò»¸öÊý¾ÝÁ¬½Ó£¬½øÐÐʵ¼ÊµÄÊý¾Ý£¨±ÈÈçÎļþ£©´«Êä¡£Ò»µ©Êý¾Ý´«ÊäÍê³É£¬Êý¾ÝÁ¬½Ó»á»°¾Í±»³·Ïú£¬µ«¿ØÖÆÁ¬½ÓÒÀÈ»´æÔÚ£¬¿Í»§¿ÉÒÔ¼ÌÐø·¢³öÃüÁî¡£Ö±µ½ÀμǼüÈëCLOSEÃüÁî³·Ïú¿ØÖÆÁ¬½Ó£¬ÔÙ¼üÈëQUITÍ˳öFTP»á»°¡£´Ëʱ˫·½¿ØÖƽø³Ì¾Í²»ÔÙ´æÔÚÁË¡£
FTPÁ¬½ÓµÄ½¨Á¢
ÔÚÒ»¸öFTP»á»°ÖУ¬ÐèÒª½¨Á¢Ò»¸ö¿ØÖÆÁ¬½ÓºÍÈô¸É¸öÊý¾ÝÁ¬½Ó¡£
½¨Á¢¿ØÖÆÁ¬½ÓµÄ¹ý³Ì´ó¼Ò¶¼ºÜÊìϤ¡£FTP·þÎñÆ÷µÄ¹«È϶˿ÚÊÇ21¡£¿Í»§¿ØÖƽø³ÌÉêÇëÒ»¸öËæ»ú·ÖÅäµÄ±¾µØ¶Ë¿Úºó£¬Óó£¹æµÄ·½·¨¿ÉÒÔÓë·þÎñÆ÷¶Ë¿Ú21½¨Á¢Ò»¸öÁ¬½Ó¡£
Êý¾ÝÁ¬½ÓµÄ½¨Á¢¾ÍûÓÐÄÇô¼òµ¥ÁË¡£ÔÚ½¨Á¢Êý¾ÝÁ¬½ÓµÄ¹ý³ÌÖУ¬¿Í»§¿ØÖƽø³Ì·´¿ÍΪÖ÷£¬³ÉΪÁ¬½ÓµÄ½ÓÊÕÕߣ¬¶ø·þÎñÆ÷Êý¾Ý´«Êä½ø³Ì³ÉÁËÁ¬½ÓµÄÇëÇóÕß¡£×÷Ϊһ¸öеÄ×Ó½ø³Ì£¬·þÎñÆ÷´«Êä½ø³Ì¿ÉÒÔÉêÇëÒ»¸öеĶ˿ںÅÀ´½¨Á¢×Ô¼ºµÄÏà¹ØÁ¬½Ó£¨Ò»°ãÊÇÀûÓÃFTPµÄ±£Áô¶Ë¿ÚºÅ20£©£¬¶øËüÏòÄĸö¿Í»§¶Ë¿Ú·¢ËÍÁ¬½ÓÇëÇóÄØ£¿ÒªÖªµÀ¿Í»§ÊÇûÓй«È϶˿ڵģ¬Õâʱ¾ÍÒªÀûÓõ½¿ØÖÆÁ¬½Ó£¬¿Í»§¿ØÖƽø³Ìͨ¹ý¿ØÖÆÁ¬½Ó¸æÖª·þÎñÆ÷½ø³Ì×Ô¼ºµÄÊý¾ÝÁ¬½Ó¶Ë¿ÚºÅ£¬·þÎñÆ÷¿ØÖƽø³Ì½«Ëüת¸æ×Ô¼ºµÄÊý¾Ý´«Êä½ø³Ì£¬·þÎñÆ÷Êý¾Ý´«Êä½ø³Ì±ã¿ÉÒÔÀûÓÃËüÓë¿Í»§½¨Á¢Êý¾ÝÁ¬½Ó¡£
FTPÃüÁ
¡°!¡±»òÕß¡°*SYSCMD¡±:Óû§¿ÉÒÔÔÚFTPģʽÖÐÖ´Ðб¾µØAS/400µÄÃüÁî¡£ÔÚʵ¼Ê¹¤×÷ÖУ¬ÕâÒ»ÃüÁî·Ç³£ÓÐÓã¬Äã²»ÓÃÍ˳öFTPģʽ¾Í¿ÉÒÔÖ±½ÓÖ´Ðб¾µØAS/400µÄÃüÁî¡£
¡°DIR¡±£ºÁгöÔ¶³ÌAS/400ij¸öĿ¼ÖеÄFILESºÍMEMBERS¡£ÈôÄãÖ´ÐÐÁË¡°PUT¡±²Ù×÷£¬Óá°DIR¡±ÃüÁî²é¿´ÊÇ·ñ½«Îļþ´«µ½ÁËÔ¶³ÌAS/400ÖС£
¡°PWD¡±£ºÁгöÔ¶³ÌϵͳµÄµ±Ç°Ä¿Â¼ÖеÄFILESºÍMEMBERS¡£
¡°LPWD¡±£ºÁгö±¾µØϵͳµÄµ±Ç°¹¤×÷Ŀ¼ÖеÄFILESºÍMEMBERS¡£
¡°PUT¡±£º½«Îļþ´Ó±¾µØϵͳ·¢Ë͵½Ô¶³Ìϵͳ¡£
¡°MPUT¡±£º½«¶à¸öÎļþ´Ó±¾µØϵͳ·¢Ë͵½Ô¶³Ìϵͳ¡£
¡°GET¡±£º´ÓÔ¶³Ìϵͳ´«Îļþµ½±¾µØϵͳ¡£
¡°MGET¡±£º´ÓÔ¶³Ìϵͳ´«¶à¸öÎļþµ½±¾µØϵͳ¡£
¡°ASCII¡±£º¸Ä±äµ½ASCIIģʽ¡£
¡°BINARY¡±£º¸Ä±äµ½BINARYģʽ¡£
¡°EBCDIC¡±£º¸Ä±äµ½EBCDICģʽ¡£
Ìرð×¢Ò⣺½«º¬ÓÐÊýÖµÀàÐ͵ÄÎļþ´ÓAS/400·¢Ë͵½ASCIIϵͳʱ£¬Ó¦½«ÎļþÖеÄÊýÖµ×ֶθÄΪZONEDÀàÐÍ£¬¶ø²»ÊÇPACKEDÀàÐÍ£¬·ñÔò½«·¢Éú²»¿ÉÔ¤²âµÄ½á¹û¡£
¡°RENAME¡±£º¸ü¸ÄÔ¶³ÌϵͳÖеÄÎļþÃû¡£
¡°QUOTE¡±£ºÖ´ÐÐÔ¶³Ì·þÎñÆ÷¶ËµÄÃüÁî¶ø²»ÓÃÖØеǼԶ³Ìϵͳ¡£
¡°LCD¡±£º¸Ä±ä±¾µØϵͳµÄµ±Ç°Ä¿Â¼¡£
¡°CD¡±£º¸Ä±äÔ¶³ÌϵͳµÄµ±Ç°Ä¿Â¼¡£
¡°CDUP¡±£º½øÈëÔ¶³ÌϵͳµÄ¸¸Ä¿Â¼¡£
¡°LOCSTAT¡±£ºÏÔʾ±¾µØ״̬ÐÅÏ¢¡£
ÅäÖÃAS/400¡¡FTP·þÎñÆ÷
Óû§ÒªÅäÖÃAS/400 FTP·þÎñÆ÷ÖУ¬ÐèÒªÓÐ*IOSYSCFGÌØȨ¡£
A¡¢ÅäÖÃTCP/IP¡£
B¡¢ÐÞ¸ÄFTPÊôÐÔ¡£¡¡ÃüÁîÊÇCHGFTPA£¨¶ÔQUSRSYS/QATMFTP.CONFIGÊý¾Ý¿âÎļþ½øÐÐÐ޸ģ©¡£
Ö÷Òª²ÎÊý˵Ã÷£º
Autostart
Servers : µ±Autostart
ServersΪ*YESʱ£¬Ò»µ©TCP/IPÆô¶¯£¬FTP·þÎñÆ÷Ò²½«×Ô¶¯Æô¶¯¡£
Number of Initial Servers:
FTP·þÎñÆ÷³õʼÆô¶¯ÊýÁ¿¡£¸ù¾ÝFTPµÄÁ÷Á¿¶ø¶¨£¬³õʼֵΪ3Ò»°ã¾Í×ã¹»ÓÃÁË¡£
Inactivity Timeout: Ö¸³öFTP¿Í»§¶ËÓë·þÎñÆ÷¶ËÔÚ¶àÉÙÃëûÓн»»¥ºó£¬Á¬½Ó½«×Ô¶¯¶Ï¿ª¡£È±Ê¡ÖµÎª300Ã루5·ÖÖÓ£©¡£
Coded character set identifyier:¡¡È±Ê¡ÖµÎª00819,ËùÓб»´«ÈëµÄASCII×Ö·û½«±»·Òë³ÉEBCDIC
500´úÂëÒ³¡£Ò²¿ÉÒÔÖƶ¨Äã×Ô¼ºµÄת»»±í¡£
Initial name format: ȱʡֵΪ*LIBL£¬½«ËùÓÐFTP·þÎñÆ÷µÄÃüÃûÐÎʽÉèΪNAMEFMT£½0£»Èô´ËֵΪ*PATH£¬ÔòNAMEFMT=1¡£
Initial directory: ȱʡֵΪ*CURLIB£¬ÒԵǼFTP·þÎñÆ÷µÄÓû§µÄµ±Ç°Ä¿Â¼ÎªFTP»á»°µÄµ±Ç°Ä¿Â¼£»Èô´ËֵΪ*HOMEDIRʱ£¬FTP»á»°µÄĿ¼ÒÔÓû§¼òÒª±íµÄHOMEDIR²ÎÊýΪ׼¡£
New file CCSID:¡¡Ö¸¶¨Óû§FTP´´½¨ÎļþµÄCCSIDÖµ¡£
Æô¶¯ÓëÍ£Ö¹FTP·þÎñÆ÷
¡¡¡¡¡¡¡¡ÊÖ¹¤Æô¶¯FTP·þÎñÆ÷£¬ÔÚAS/400ÃüÁîÐÐÊäÈ룺
STRTCPSVR *FTP
ÊÖ¹¤Í£Ö¹ËùÓÐFTP·þÎñÆ÷£¬ÔÚAS/400ÃüÁîÐÐÊäÈ룺
ENDTCPSVR *FTP
×¢Ò⣺
ÒòΪֱ½ÓÓÃENDTCPSVR *FTPÃüÁîÍ£Ö¹FTP·þÎñÆ÷£¬Óû§¿ÉÄܻᶪʧÊý¾Ý£¬ÎªÁ˱£Ö¤Óû§²»¶ªÊ§Êý¾Ý£¬Ó¦¸Ã°´ÕÕÒÔϲ½Öè½øÐд¦Àí£º
A¡¢ÔÚAS/400µÄÃüÁîÐÐÊäÈ룺
WRKACTJOB SBSD(QSYSWRK)
²éÕÒÊÇ·ñÓÐQTFTPxxxxx(xxxxx´ú±í5λÊý×Ö)´æÔÚ£¬ÈôûÓУ¬Ôò¿ÉÒÔÖ´ÐÐENDTCPSVR *FTPÃüÁÈôÓУ¬ÔòºÚÐÄ×öÏÂÒ»²½¡£
B¡¢È·±£Ã»ÓÐÓû§µÇ¼FTP·þÎñÆ÷¡£ÔÚAS/400µÄÃüÁîÐÐÊäÈ룺
NETSTAT *CNN
²éÕÒÊÇ·ñÓÐLOCAL PORTΪ FTP-CON״̬ΪESTABLISHEDµÄÁ¬½Ó´æÔÚ£¬ÈôûÓÐÔò¿ÉÒÔÖ´ÐÐÏÂÒ»²½£»ÈôÓУ¬Ó¦¸ÃµÈµÈÓû§µÄFTP½áÊøºóÔÙÖ´ÐÐÏÂÒ»²½¡£
C¡¢ÔÚAS/400µÄÃüÁîÐмüÈ룺
ENDTCPSVR *FTP
Åú·½Ê½FTP
¡¡¡¡¡¡¡¡FTP±»Éè¼ÆΪ½»»¥Ê½TCP/IPÓ¦Ó㬵«AS/400Ò²Ö§³ÖFTPÅú´¦Àí·½Ê½¡£
¡¡¡¡¡¡¡¡FTPÅú´¦Àí·½Ê½Ó¦¸Ã°´ÕÕÈçϲ½ÖèÀ´½øÐУº
3.2.5
´´½¨Ò»¸öCL³ÌÐòÀ´Æô¶¯FTP¡£
3.2.5
´´½¨Ò»¸öº¬ÓÐËùÓн»»¥·½Ê½FTPÃüÁîµÄÔ´ÎïÀíÎļþµÄ³ÉÔ±¡£
3.2.5
Ìá½»Åú×÷ÒµÔËÐÐÕâ¸öCL³ÌÐò¡£
3.2.5
¼ì²é½á¹û¡£
ÓÉÓÚPCʹÓÃASCII±àÂë, ¶øÔËÐÐOS/400µÄAS/400ʹÓÃEBCDIC±àÂë,
ËùÒÔÔÚÁ½¸ö²»Í¬±àÂëµÄ²Ù×÷ϵͳ֮¼ä»¥Ïà´«ËÍÎļþ, ¾ÍÉæ¼°µ½Îļþ±àÂëµÄÎÊÌâ. Èç¹ûÒª´«ÊäµÄÎļþÓÖ°üº¬ÖÐÎÄ, ÄÇôϵͳÓÖÒª×ö²»Í¬µÄתÂë´¦Àí.
A. ´ÓPCÍùAS/400ËÍÎļþ:(PC
--> Client, AS/400 --> Server)
ʾÀý: ½«PCÉÏe:\tempĿ¼ÏµÄÎļþtest.file(°üº¬ÖÐÎÄ), ´«Ë͵½AS/400ÉϵĿâTESTLIBÖÐ
* ÔÚWindowsÖÐÔËÐÐDOS´°¿Ú;
* ftp as400-ip-address;
* ÊäÈëÓû§ÃûºÍÃÜÂë;
* quote site namefmt
1
* cd
/qsys.lib/testlib.lib
* lcd
e:\test
* bin
* quote type c 1381
* put test.file
B. ´ÓAS/400ÍùPCËÍÎļþ:(PC
--> Server, AS/400 --> Client)
ʾÀý: ½«AS/400ÉÏ¿âTESTLIBϵÄÎļþtest.file(°üº¬ÖÐÎÄ), ´«Ë͵½PCÉϵÄĿ¼e:\tempÖÐ
* ÔÚAS/400ÃüÁîÐÐÊäÈë: ftp
'pc-ip-address'
* ÊäÈëÓû§ÃûºÍÃÜÂë;
* cd
e:\temp
* namefmt
1
* lcd
/qsys.lib/testlib.lib
* bin
* ltype
c 1381
* put testas.file
×¢£ºÒÔÏÂÊÇOS/400µÄ°²×°¹ý³Ì¡£ÒÔ°²×°OS/400 V5R1ΪÀý¡£
µÚÒ»²½£º°²×°ÄÚÂ루´óÔ¼ÐèÒª1µ½1.5¸öСʱ£©
¡¡¡¡½«»úÆ÷Æô¶¯·½Ê½µ÷Ϊ01DM£¬¼´´Ó¹âÇý£¨´Å´ø»úÖв»Òª·Å´Å´ø£©ÊÖ¶¯Æô¶¯¡£
¡¡¡¡ ˵Ã÷¡ª¡ªÆô¶¯·½Ê½£º¡¡¡¡A£º´ÓÓ²Å̺ÍÓÀ¾ÃPTFÇøÆô¶¯£»B:´ÓÓ²Å̺ÍÁÙʱPTFÇøÆô¶¯£»D:´Ó¹âÇýÆô¶¯
¡¡ ÔÚ¹âÇýÖзÅÈë¹âÅÌI£ßBASE£ß01£¬ÌØÐíÄÚÂëÅÌ¡£
ÔÚLANGUAGE
FEATURE´¦Ìî2984£¬ÇÃÖ´Ðмü£¬ÔÚ Confirm Language GroupÆÁÄ»³öÏÖʱ£¬ÇÃÖ´Ðмü£¬È·ÈÏÄãÑ¡ÔñµÄÓïÑÔ2984£¨Ö§³ÖË«×Ö½Ú×Ö·û¼¯µÄÓ¢ÎÄ£©¡£
ÔÚInstall Licensed Internal Code²Ëµ¥ÆÁÄ»ÉÏÑ¡Ôñ
1--Install Licensed Internal Code£¬È»ºóÇÃÖ´Ðмü¡£
ÔÚInstall Licensed Internal Code²Ëµ¥ÆÁÄ»ÉÏÑ¡Ôñ
2--Install Licensed Internal Code £¨LIC£© and
Initialize system£¬È»ºóÇÃÖ´Ðмü¡£
ÔÚInstall Licensed Internal Code and Initialize
system-warningÆÁÄ»ÉÏÖ±½ÓÇÃÖ´Ðмü¡£
ÔÚInstall Licensed Internal Code £¨LIC£© and Initialize
system-confirmationÆÁÄ»ÉÏÇÃF10¡ªcontinue to
Install£¬½øÈëInitialize the Disk¡ªStatusÆÁÄ»¡£µÈ´ý£¬È»ºó½øÈëInstall Licensed
Internal Code £¨LIC£©-statuesÆÁÄ»£¬Íê³Éºó£¬»úÆ÷»á×Ô¶¯IPL£¬IPL·½Ê½×Ô¶¯±äΪ
IPLÍê³Éºó£¬½øÈëDisk Configuration Attention
ReportÆÁÄ»¡£
ÔÚ´ËÆÁÄ»ÉÏ°´F10-Accept the
problems and continue¼ÌÐø
µÚ¶þ²½£º°²×°²Ù×÷ϵͳ£¨2-3Сʱ£©
ÔÚIPL or Install the System²Ëµ¥ÆÁÄ»ÉÏ£¬
Ñ¡Ôñ2¡ªInstall the Operation System £¬ÇÃÖ´Ðмü£¬½øÈëConfirm
Install of OS/400ÆÁÄ»£¬ÇÃÖ´ÐмüÈ·ÈÏ¡£½øÈëSelect a Language GroupÆÁÄ»¡£ÔÚ Language
Featureºó±ßÌî2984È»ºóÇÃÖ´Ðмü¡£½øÈëconfig
Language Feature selectionÕâһȷÈÏÆÁÄ»£¬ÔÚ´ËÆÁÄ»ÇÃÖ´Ðмü£¬½øÐÐÈ·ÈÏ¡£
½øÈëAdd All Disk Units to the System²Ëµ¥ÆÁÄ»¡£ÔÚÕâÒ»ÆÁÄ»ÖпÉÒÔ¸ù¾Ý²»Í¬Çé¿ö×ö³ö²»Í¬µÄÑ¡Ôñ¡£ÎÒÕâÀï°´ÖØÐÂÅäÖÃÓ²ÅÌ,²¢ÇÒ°ÑËùÓÐÓ²ÅÌ×öµ½Ò»¸öASPÖÐÀ´×ö¡£
Ñ¡Ôñ²Ëµ¥ÖеÄ4¡ªAdd All the Disk units to the System ASP and
balance data
×¢£º
ÕâÀï3ºÍ4µÄÇø±ðÊÇ£º3Ö»¼òµ¥µØ°ÑËùÓдÅÅ̼ӵ½Ò»¸öASPÖУ¬¶ø4²»½ö°ÑËùÓеĴÅÅ̼ӵ½Ò»¸öASPÖУ¬²¢ÇÒ½øÐÐÊý¾Ýƽºâ²Ù×÷¡£
´ÅÅÌÅäÖÃÍê±Ïºó½øÈëLIC¹«Ë¾IPL ProgressÆÁÄ»¡£
µÈ´ý£¬µ½Ìáʾ»»ÅÌʱÔÚ¹âÇýÖзÅÈë¹âÅÌB2984_01£¬È»ºóÇÃÖ´Ðмü¼ÌÐø¡£
ÔÚ°²×°²Ù×÷ϵͳµÄ¹ý³ÌÖÐÒªÇóÄãÊäÈëÈÕÆÚ¡¢Ê±¼äµÈ¡£¸ù¾ÝÌáʾ»»¹âÅÌ¡£
µÚÒ»´Î³öÏֵǼ½çÃæʱ£¬ÓÃÓû§QSECOFR½øÐеǼ£¨Ã»ÓпÚÁҲ²»ÐèÒª¿ÚÁ¡£
ÔÚIPL
OptionÒ»ÆÁÖÐÒ»°ã²»ÐèÒª½øÐÐÈκÎÉèÖã¬Ö±½Ó°´Ö´Ðмü£¬½øÈëSet Major System OptionÕâÒ»ÆÁ£¬Ò»°ã¶øÂÛÒ²²»ÐèÒª½øÐÐÈκÎÉèÖã¬Ö±½ÓÇÃÖ´Ðмü¡£
ÔÙ´ÎÆô¶¯ºó£¬ÏµÍ³»áÒªÇóÄãÐÞ¸ÄQSECOFRÓû§µÄÃÜÂë¡£(ĬÈÏ¿ÚÁîΪ£ºQSECOFR)
ÖØÐÂÆô¶¯»úÆ÷£¬½øÈëDST¡£ÅäÖôÅÅÌ£¬×öRAID±£»¤ºÍ¾µÏñ±£»¤¡£
ÅäÖôÅÅ̵ľßÌå²½Ö裺
½øÈëSST£¬Ñ¡Ôñ3-work
with disk units£¬½øÈëºó£¬Ñ¡Ôñ
2-Work with disk Configuration£¬½øÈëºó£¬Ñ¡Ôñ
2-Add units to ASPs£¬½øÈëºó£¬ÔÚÄãÒª¼ÓÈëµÄ´ÅÅÌÇ°ÃæÌîдASPºÅ£¬Èç1´ú±í¼ÓÈëµ½ASP1£¬2´ú±í¼ÓÈëµ½ASP2£¬µÈ
°²×°ÌØÐí³ÌÐò£¨3µ½4Сʱ£©
·ÅÈëB2984_02 Ãâ·ÑÌØÐí³ÌÐòÅÌ¡£
CHGMSGQ QSYSOPR *BREAK SEV(60)
ENDSBS *ALL
*IMMEDCHGMSGQ QSYSOPR SEV(95)
GO LICPGM²¢Ñ¡ÊÖ¶¯°²×°È«²¿Ö®ËùÓвúÆ·£¬°²×°É豸OPT01£¬¿ªÊ¼°²×°¡£
³öÏÖÌáʾҪÇó×°ÈëÏÂÒ»ÕŽéÖÊ£¬X£ºÎÞÏÂÒ»ÕÅ£¬G£ºÒÑ×°ÈëÏÂÒ»ÕÅ¡£
·ÅÈëF2984_01¸½¼ÓÌØÐí³ÌÐòÅÌ¡£
GO LICPGM²¢Ñ¡ÊÖ¶¯°²×°È«²¿Ö®ËùÓвúÆ·£¬°²×°É豸OPT01£¬¿ªÊ¼°²×°¡£
ÔÚLICPGM²Ëµ¥£¬Ñ¡50ÏÔʾ¶ÔÐÅÏ¢µÄ¼Ç¼£¬ÑéÖ¤°²×°Çé¿ö¡£
°²×°PTF£¨8µ½10Сʱ£©
IPLģʽÉèΪNORMAL£¬ÓÃQSECOFRµÇ¼¡£
·ÅÈëC9152410_01ÀÛ»ýPTFÅÌ¡£
CHGMSGQ QSYSOPR *BREAK SEV£¨70£©¡£
GO PTF£¬Ñ¡Ïî8°²×°È«²¿PTF°ü£¬Automatic IPL optionÉèΪN¡£
°²×°Íê³Éºó£¬
ENDSBS *ALL *IMMED
DSPMSG QSYSOPR
µ±System ended to restricted conditionÐÅÏ¢³öÏֺ󣬹ػú¡£
PWRDWNSYS OPTION£¨*IMMED£© RESTART£¨*YES£© IPLSRC£¨B£©
°²×°PTFºó£¬ÖØÆô¶¯£¬Ó¦´ÓBÆô¶¯¡£
ÔÚLICPGM²Ëµ¥£¬Ñ¡50ÏÔʾ¶ÔÐÅÏ¢µÄ¼Ç¼£¬ÑéÖ¤°²×°Çé¿ö¡£
°²×°µÚ¶þÓïÑÔ£¨1-2Сʱ£©
ÓÃQSECOFRµÇ¼¡£
·ÅÈëL2989_01ÖÐÎĵڶþÓïÑÔÅÌ¡£
CHGMSGQ QSYSOPR *BREAK SEV£¨95£©¡£
GO LICPGM£¬Ñ¡21°²×°¸¨ÖúÓïÑÔ£¬Ñ¡2989ÖÐÎÄ¡£
°²×°½áÊøºó£¬¸ÄϵͳֵWRKSYSVAL
QSYSLIBL£¬ÔÚQSYSÇ°¼ÓÈëQSYS2989¿â¡£
ÐÞ¸Äϵͳֵ
QAUTOCFG 1
QAUTORMT 1
QAUTOVRT *nomax
QLMTSECOFR 0
QSECURITY 40
QCTLSBSD QCTL £¨Ê¹ÓÃÓÚnormal»úÆ÷£©£¨¶ÔÓÚDSD»úÆ÷£¬Ó¦ÎªQBASE£©
QCNTRYID CN
QDATE
QTIME
AS400°²×°ÖÐÎĵڶþÓïÑÔºó£¬ÓÃWRKSYSVAL QSYSLIBLÃüÁîÐÐÖ¸Á½«QSYS2989¿â¼ÓÈ룬עÒâ¼ÓÔÚQSYS¿âµÄÇ°Ã棬ÕâÑù²Ëµ¥ºÍ°ïÖú¾Í¶¼ÊÇÖÐÎÄÁË¡£
ÐÞ¸ÄÐí¿É³ÌÐòÓû§Êý
WRKLICINF
ΪÁË°²È«£¬½¨Á¢Ò»¸öÓëQSECOFRÓÐÏàµÈȨÏÞµÄÓû§×÷ΪQSECOFRµÄ±¸·Ý¡£
1. ËøµÄÎåÖÖÀàÐÍ
(1) Exclusive(*EXCL): Ö»ÓиÃËøµÄ·¾¶Ñ¡Ôñ¹ý³Ì(routing step)²Å¿ÉÄÜʹÓøöÔÏó£»
ÔÚÆäËûÈÎÎñÖеÄ·¾¶Ñ¡Ôñ¹ý³Ì²»ÄÜ´æÈ¡¸Ã¶ÔÏó¡£
(2) Exclusive-allow-read(*EXCLRD): Õ¼ÓøÃËøµÄ·¾¶Ñ¡Ôñ¹ý³Ì¿ÉÄܶÁ»ò¸üиöÔÏó£¬
¶øÆäËûÈÎÎñÖеÄ·¾¶Ñ¡Ôñ¹ý³ÌÖ»ÄܶÁËü¡£
(3) Shared-for-update(*SHRUPD): Õ¼ÓøÃËøµÄ·¾¶Ñ¡Ôñ¹ý³ÌÒÔ¼°ÔÚÆäËûÈÎÎñÖеÄ·¾¶
Ñ¡Ôñ¹ý³ÌÊÇ¿ÉÒÔ¶Á»ò¸üиöÔÏó¡£
(4) Shared-no-update(*SHRNUP): Õ¼ÓøÃËøµÄ·¾¶Ñ¡Ôñ¹ý³ÌÖ»¿ÉÒÔ¶Á¸Ã¶ÔÏ󣻶øÔÚÆäËû
ÈÎÎñÖеÄ·¾¶Ñ¡Ôñ¹ý³ÌÒ²ÊÇÖ»¶Á¸Ã¶ÔÏó¡£
(5) Shared-for-read(*SHRRD): Õ¼ÓøÃËøµÄ·¾¶Ñ¡Ôñ¹ý³ÌÖ»¿ÉÒÔ¶Á¸Ã¶ÔÏ󣻶øÔÚÆäËû
ÈÎÎñÖеÄ·¾¶Ñ¡Ôñ¹ý³ÌÊÇ¿ÉÒÔ¶Á»ò¸üиöÔÏó¡£
2. ȱʡÇé¿öÏ£¬CLºÍHLL(¸ß¼¶ÓïÑÔ³ÌÐò£©³ÌÐòÖ»ÔÚÊäÈë(I)ÎïÀíÎļþ³ÉÔ±µÄÊý¾ÝÉÏ·ÅÖÃ*SHRRDËø£¬²¢ÔÚÖ»Êä³ö(O)ºÍÊäÈë-Êä³ö(U)ÎïÀíÎļþ³ÉÔ±µÄÊý¾ÝÉÏ·ÅÖÃ*SHRUPDËø¡£
ºóÃæÕâÒ»¾ä²»ÊǺÜÀí½â£¬ÎªÊ²Ã´O/UÀàÐ͵ÄÎļþ²»·Å*EXCLRDËøÄØ£¿¸öÈËÀí½âÓ¦ÊÇÖ»ÔÊÐíµ±Ç°³ÌÐò¸üУ¬ ±ðµÄ³ÌÐòÖ»ÄܶÁ¡£ÐèÒª¸ßÊÖÖ¸½Ì£¡
3. ÏÔʾ¶ÔÏó(object)ºÍ¼Ç¼(record)µÄËøÓÐÈý¸öÃüÁ
(1) wrkobjlck: ²é¿´ÓÉËùÓÐÈÎÎñÔÚÒ»¸ö¶ÔÏóÉÏʹÓõÄlock¡£
(2) dsprcdlck(display
record locks): ²é¿´Ò»¸öÎïÀíÎļþÖÐÒÑËø¶¨µÄ¼Ç¼.
(3) dspjob: ²é¿´Ò»¸öÈÎÎñµÄËùÓÐÍⲿËø£¬°üÀ¨ÒÑʹÓõÄÄÇЩËøºÍ¸ÃÈÎÎñÕýµÈ´ýʹÓõÄÄÇЩËø¡£
3.2.7.1
Journal
µÄ¸ÅÄîÒÔ¼°×÷ÓÃ
3.2.7.2
ÈçºÎΪһ¸öÎïÀíÎļþ´´½¨Ò»¸öjournal
A.
Create one
journal rceiver
B.
Create one
journal
C.
Start one PF
for the journal
D.
create log
file
Use WRKQRY command to create one PF and the first
10 field should be:
And join every fields in RCM file.
Use ¡°define result fields¡±
define the temp fields
E.
Source code
/************* CL SOURCE CODE
*************************************************************/
/* USE QUERY SULL611O/JRNRCMQ1
DEFINE RCMJRNPF DATABASE FILE
*/
/* THE RECORD
LENGTH OF RCM IS: 1551
*/
/*
*/
/* IF YOU WANT
RETRIEVE WHO CHANGE/UPDATE/DELETE THE FILE
*/
/* SO YOU NEED THE FIRST 66
CHARACTER IN THE JRN STRING.
*/
/*
*/
/* If ENTFMT(*TYPE1) is specified,
*/
/* then the format
of the fields in the retrieved entry is as follows:
*/
/* FIELD NAME
FIELD ATTRIBUTES
*****
*/
/* ENTRY
LENGTH
TYPE(*DEC) LEN(5 0)
*****
*/
/* SEQUENCE
NUMBER
TYPE(*DEC) LEN(10 0)
*****
*/
/* JOURNAL
CODE
TYPE(*CHAR) LEN(1)
***** */
/* JOURNAL ENTRY
TYPE TYPE(*CHAR)
LEN(2)
*****
*/
/* DATE
TYPE(*CHAR) LEN(6)
*****
*/
/* TIME
TYPE(*DEC) LEN(6 0)
*****
*/
/* JOB NAME
TYPE(*CHAR) LEN(10)
*****
*/
/* USER NAME
TYPE(*CHAR) LEN(10)
*****
*/
/* JOB NUMBER TYPE(*DEC) LEN(6 0)
*****
*/
/* PROGRAM
NAME
TYPE(*CHAR) LEN(10)
*****
*/
/* OBJECT NAME
TYPE(*CHAR) LEN(10)
*/
/* OBJECT
LIBRARY
TYPE(*CHAR) LEN(10)
*/
/* MEMBER NAME
TYPE(*CHAR) LEN(10)
*/
/* COUNT/RRN
TYPE(*DEC) LEN(10 0)
*/
/* FLAG
TYPE(*CHAR) LEN(1)
*/
/* COMMIT CYCLE
ID
TYPE(*DEC) LEN(10 0)
*/
/* INCOMPLETE
DATA
TYPE(*CHAR) LEN(1)
*/
/* MINIMIZED ENTRY
DATA TYPE(*CHAR)
LEN(1)
*/
/* RESERVED
TYPE(*CHAR) LEN(6)
*/
/* ENTRY-SPECIFIC
DATA TYPE(*CHAR)
LEN(UP TO 9844)
*/
/*
*/
/*
*/
/* for more info. you can browse from:
*/
/*
http://publib.boulder.ibm.com/iseries/v5r2/ic2989/index.htm?info/cl/rtvjrne.htm */
/*
*/
/*******************************************************************************************/
PGM
DCL VAR(&RTNENT) TYPE(*CHAR) LEN(1676)
DCL VAR(&RTNENT2) TYPE(*CHAR) LEN(1617)
DCL VAR(&SEQUNC) TYPE(*DEC) LEN(10) VALUE(1)
MONMSG MSGID(CPF0000) EXEC(GOTO CMDLBL(ENDPGM))
CLRPFM FILE(RCMJRNPF)
LOOP1: RTVJRNE JRN(BPCS
FROMENT(&SEQUNC) ENTTYP(PT PX UB UP) +
ENTFMT(*TYPE1) RTNJRNE(&RTNENT)
CHGVAR VAR(&SEQUNC) VALUE(%SST(&RTNENT 6 10))
CHGVAR VAR(&RTNENT2) VALUE((%SST(&RTNENT 1 66)) +
*CAT (%SST(&RTNENT 126 1551)))
CALL
PGM(JRNRCDB) PARM(&RTNENT2)
CHGVAR VAR(&SEQUNC) VALUE(&SEQUNC + 1)
GOTO
CMDLBL(LOOP1)
ENDPGM: ENDPGM
/*******************************************************************************************/
F* RPGLE SOURCE CODE
F*
about Journal help info. you can refer to:
F*
http://publib.boulder.ibm.com/iseries/v5r2/ic2989/index.htm?info/cl/rtvjrne.htm
F*
F*
F*****************************************************************
FRCMJRNPF O E
DISK
RENAME(RCMJRNPF:IPR
F*****************************************************
D RCMDS
E DS
EXTNAME(RCMJRNPF)
C *entry plist
C
PARM
pSTRING 1617
C
EVAL
RCMDS = PSTRING
C
WRITE IPR
C
RETURN
Library |
Object |
Remark |
SULL611O |
JRNRMCQ1 |
Create RCMJRNPF file |
BPCS |
RCMJNRPF |
Save log of RCM |
SULL611O |
JRNRCDC |
Main program |
SULL611O |
JRNRCDB |
Call by JRNRCDC |
F.
Structure of
RCMJRNPF
o PT - Record added to physical file member
o PX
- Record added directly to physical file member
o UB
- Before-image of record updated in physical file member
o UP
- After-image of record updated in physical file member
ÏÖÔÚÄã¿ÉÒÔʹÓÃÕâ¸öexcel¸ñʽȥ¸ú×ÙËÐÞ¸ÄÁ˼Ǽ